View Grant Opportunity
Cooperative Agreement for affiliated Partner with Northern Great Plains Cooperative Ecosystem Studies Unit
Geological Survey
G27AS00052
DOI-USGS1
General Information
Est. Program Funding:
Closing Date:
Expected No. of Awards
Award Ceiling
Opportunity Number:
G27AS00052
Owning Agency:
DOI-USGS1
Opportunity Category:
Discretionary (D)
Synopsis
Robust and reliable quantitative method to correct for solution chemistry interferences in molecularly imprinted polymer – electrochemical sensor (MIP-ES) measurements of complex environmental water matrices The goal of this research is to develop a robust and reliable quantitative method to correct for solution chemistry interferences in MIP-ES measurements of complex environmental water matrices. One of the challenges using MIP-ES to measure contaminants such as per- and polyfluoroalkyl substances (PFAS) in environmental samples is understanding how bulk solution chemistry contributes to the electrochemical background signal. The development of a ratiometric comparison approach with MIP-ES will involve bench scale proof of concept testing and then escalate to field deployed trials. Instrumentation required for MIP-ES fabrication and sensing includes multichannel potentiostats capable of differential pulse voltammetry and cyclic voltammetry. Differential pulse voltammetry will be used to collect current differences at 1-minute and 15-minute incubation time points in the sample matrices. These current values will be used to build the ratiometric comparison approach. The ratiometric approach will involve the comparison of normalized current difference ratios, outlined in Equation 1, between a matrix matched solution that contains all matrix constituents minus the analyte in question and an unknown solution that is composed of the sample matrix and may or may not contain the analyte.
The use of a ratiometric comparison isolates current differences from the association of the analyte with the MIP-ES binding sites from any change in current from interferent effects due to the rest of the sample matrix constituents (i.e., humic acids, fulvic acids, ions, non-fluorinated counterparts, etc.). A ratio close to 1 indicates the absence of the analyte due to similar normalized current difference values in the ratio. A statistically different ratio from 1 indicates the presence of the analyte in question in the sample matrix. This project supports the administration's priority to protecting human health by generating data and tools that identify potential risks to drinking water quality. By enabling early detection and informed decision-making, this work helps safeguard communities from exposure to harmful contaminants and ensures access to safe, clean drinking water. |
|
| Response Date | Nov 14, 2026 12:00:00 AM EST |
| Posting Date | Oct 14, 2026 12:00:00 AM EDT |
| Archive Date | |
| Award Ceiling | 450,000 |
| Award Floor | 1 |
| Cost Sharing | No |
Eligibility
| Eligible Applicants | Others (see text field entitled "Additional Information on Eligibility" for clarification) |
| Additional Info on Eligibility: | This financial assistance opportunity is being issued under a Cooperative Ecosystem Studies Units (CESU) Program. CESU's are partnerships that provide research, technical assistance, and education. Eligible recipients must be a participating partner of the Northern Great Plains Cooperative Ecosystem Studies Unit. |
Additional Information
| Agency Name | Geological Survey |
| Link to Additional Information: | N/a |
| Grantor Contact Information: |
If you have difficulty accessing the full announcement electronically, please contact:
GrantSolutions Help Desk Phone: 916-278-9331 |
CFDA Program(s)
- 15.808: U.S. Geological Survey Research and Data Collection
Contact Us
Our expert team at GTC 360° Advisors can help develop your grant strategy, recruit partner organizations, write your full proposal, compile and manage your budgets, and help you submit a compelling and compliant proposal on time.